Washington, DC
DC BEPS: meet the standard, cut 20%, or pay
DC's Building Energy Performance Standards set a minimum score for each property type. Buildings below it have one compliance cycle to improve. The alternative is a payment of up to $10 per square foot, capped at $7.5 million per building.
- Covered now
- 50,000 sq ftand up for private buildings; District-owned buildings from 10,000 sq ft
- Coming next
- 25,000 sq ftjoins with the next set of standards, then 10,000 sq ft after that
- Measured by
- ENERGY STARscore for the property type, or source energy use intensity where no score exists
- Maximum payment
- $10 / sq ftof gross floor area, capped at $7.5 million per building
How the standard works
DOEE sets a performance standard for each property type at the start of every cycle. For buildings that can earn an ENERGY STAR score, the law says the standard can be no lower than the District median score for that property type. Property types that can't earn a score are held to a source energy use intensity standard instead.
Your benchmarking data decides where you land. A building at or above its standard is compliant for the cycle. A building below it must pick a compliance pathway and show results by the end of the cycle, which runs five years from the date the standards are set.
Coverage widens in steps. Private buildings of 50,000 square feet and up are covered today. Buildings from 25,000 square feet join with the next round of standards, and buildings from 10,000 square feet join after that. The Council has moved those dates before, so we track the current schedule for you rather than print it here.
The compliance pathways
Performance Pathway
Cut normalized site energy use intensity by more than 20% against the baseline set for the cycle. It's the most common route, and the one where partial progress reduces the payment most directly.
Standard Target Pathway
Raise the building's score, or lower its source EUI, to the standard for its property type. Only property types DOEE lists as eligible can use it, and it works best for buildings that start close to the line.
Prescriptive Pathway
Install a defined set of cost-effective efficiency measures and earn the required points. Useful where measured savings would be hard to prove.
Alternative compliance agreement
A negotiated plan with DOEE, held to a standard no less stringent than the other pathways.
The next cycle adds a trajectory pathway, with building-specific targets that step down toward long-term goals. Owners can also apply to delay compliance for up to three years for reasons such as a change of ownership, major renovation or pending demolition, and to be exempted for financial distress or low occupancy. Affordable housing can qualify for longer delays.
What a shortfall costs
The maximum alternative compliance payment is $10 per square foot of gross floor area, using the floor area in your most recent District benchmarking results, capped at $7.5 million per building. College, university and hospital campuses share a single cap.
DOEE reduces the payment in proportion to progress, and each pathway measures progress differently:
- Performance: the share of the required 20% site EUI reduction you achieved.
- Standard Target: how far you closed the distance to the standard, measured against the gap a building 20% less efficient than the standard would have to close.
- Prescriptive: points earned against points required.
That proration matters for capital planning. A 150,000 square foot building that achieves a 12% reduction on the Performance Pathway cuts its $1.5 million maximum by 60%, to $600,000. The last few percentage points are often the most expensive, so the right answer isn't always "spend whatever it takes to reach 20%."
Run your own numbers in the estimator on our homepage. It applies the Performance Pathway proration to your floor area.
Open the DC estimatorWhere owners get caught
- Bad benchmarking data. The wrong property type or floor area in Portfolio Manager changes the standard you are measured against and the size of the payment. Fix it before the baseline locks in, not after.
- Choosing a pathway late. The pathway decides what counts as progress. Owners who start projects first and pick a pathway later can end up with savings that don't count toward the measure DOEE uses.
- Tenant energy. Whole-building data includes tenant consumption the owner doesn't control. DOEE may allow owners to recover part of a payment from non-residential tenants, which makes lease language worth reviewing now.
- Missing the money. The DC Sustainable Energy Utility and the DC Green Bank run incentive and financing programs aimed at BEPS compliance. Sequenced well, they change which measures pencil out.
How Probitas helps
We start with a compliance gap assessment: your score against the standard, the pathways open to you, and the payment you're exposed to under each. If there's a real gap, a retrofit ROI analysis ranks the measures that close it against the cost of paying. Annual benchmarking support keeps the data clean so the plan holds. When it's time to commit to a pathway, submit Prescriptive Pathway reports or apply for a delay, our compliance filings service prepares and submits them.
Other standards we cover
Portfolios rarely sit under one law. We map every building to every standard that applies to it.
Sources. Summary as of October 2026. Rules change; confirm current requirements for your building before acting. This page is general information, not legal advice.
- D.C. Code § 8-1772.21, Establishment of a Building Energy Performance Standard Program.
- DOEE, BEPS Compliance and Enforcement Guidebook, version 1.2 (September 2026), Chapter 7.
- D.C. FY2027 Budget Support Act, Subtitle VI(P), and fiscal impact statement (July 2026).
Find out where your buildings stand
Book a 30-minute discovery call. Bring an address or a portfolio list and we'll tell you which standards apply and how far off you are.